| Brand Name: | WONDERY |
| Model Number: | HX-1200 |
| MOQ: | 1 Set/Sets |
| Price: | Negotiable |
| Delivery Time: | 30 Days |
| Payment Terms: | L/C,T/T |
HX safety and energy-saving drying ovens are used for coil varnish curing in motors, electrical equipment, transformers and electronics. Working sizes from 1200×1500×1000mm to 4000×3000×3000mm, working temperature 200℃, heating power 18-140kW, temperature uniformity ±3℃. Circulating ventilation and high-volume hot-air circulation support temperature uniformity. Typical applications include drying processes for F, H and B class motors, transformers and electrical products.
Uneven drying temperature:Irrational hot air circulation design in traditional ovens causes large temperature differentials across the working chamber – affecting varnish film curing quality. Root cause: improper air duct layout and fan selection.
High energy consumption and operating costs:Poor oven insulation and severe heat loss waste heating power. Root cause: incomplete insulation material selection and chamber sealing design.
Insufficient safety protection:Volatile gases accumulate during varnish curing – safety hazards. Root cause: lack of over-temperature alarms, fault alarms and explosion-proof design.
Missing temperature recording and traceability:Drying temperature curves cannot be automatically recorded – difficult quality traceability. Root cause: control system lacks data storage and export functions.
3.1 High-Volume Hot Air Circulation System:Circulating ventilation and high-volume hot-air circulation system ensure working chamber temperature uniformity ±3℃. Hot air circulates evenly inside the chamber – stable varnish film curing quality.
3.2 Energy-Saving Insulation Design:Chamber with high-quality insulation materials – reduces heat loss and operating energy consumption. Heating power 18-140kW matched to chamber size – avoiding power waste.
3.3 Safety Protection Configuration:Optional over-temperature alarms, automatic recording and fault alarms. Timely alarms when volatile gases accumulate during varnish curing – ensuring safety.
3.4 Temperature Recording & Traceability:Equipped with temperature recording system – drying temperature curves automatically recorded and stored – supports data export – meeting quality traceability requirements.
| Model | Working Size L×W×H (mm) | Working Temp (℃) | Power | Frequency (Hz) | Heating Power (kW) | Temp Uniformity (℃) | Weight (kg) |
|---|---|---|---|---|---|---|---|
| HX-1200 | 1200×1500×1000 | 200 | 380V | 50 | 18 | ±3 | 1100 |
| HX-1500 | 1500×1800×1600 | 200 | 380V | 50 | 27 | ±3 | 1800 |
| HX-2000 | 2200×2000×2200 | 200 | 380V | 50 | 45 | ±3 | 2100 |
| HX-2500 | 2500×2200×2500 | 200 | 380V | 50 | 54 | ±3 | 2900 |
| HX-2800 | 2800×2500×2500 | 200 | 380V | 50 | 81 | ±3 | 3800 |
| HX-3000 | 3200×3000×3000 | 200 | 380V | 50 | 128 | ±3 | 4700 |
| HX-4000 | 4000×3000×3000 | 200 | 380V | 50 | 140 | ±3 | 5800 |
Note: The above parameters are within the standard configuration range and can be customized according to workpiece size, process requirements, and factory conditions.
5.1 Recommended Scenarios
Varnish curing and drying of F, H, B class motor coils
Drying and curing of transformers and electrical products
Coil varnish curing in electronics industry
5.2 Key Selection Considerations
Workpiece size and chamber matching: Select corresponding model based on maximum workpiece dimensions
Heating power requirements: 18-140kW – calculate based on chamber size and heating rate requirements
Temperature uniformity requirements: ±3℃ – confirm varnish film curing process meets requirements
Safety configuration: Optional over-temperature alarms, automatic recording, fault alarms per process requirements
Q1: How is oven temperature uniformity ensured?
A: Circulating ventilation and high-volume hot-air circulation system – hot air circulates evenly in the working chamber – temperature uniformity ±3℃. Air duct layout and fan selection optimized to ensure consistent temperature across all zones.
Q2: Can the equipment meet drying requirements for different motor classes?
A: Suitable for drying processes of F, H, B class motors, transformers and electrical products. Working temperature 200℃ – temperature curves settable per varnish film curing process requirements.
Q3: What safety protection configurations are available?
A: Optional over-temperature alarms, automatic recording and fault alarms. Timely alarms when volatile gases accumulate during varnish curing – ensuring safety.
Q4: Can temperature curves be recorded and exported?
A: Equipped with temperature recording system – drying temperature curves automatically recorded and stored – supports data export – meeting quality traceability requirements.
Good temperature uniformity: High-volume hot air circulation – ±3℃ – stable varnish film curing quality
Energy-saving insulation design: High-quality insulation materials reduce heat loss and operating energy consumption
Comprehensive safety protection: Over-temperature alarms, fault alarms optional – ensuring drying safety
Temperature recording and traceability: Curves automatically recorded and stored – supports data export
Full range coverage: Working sizes from 1200×1500×1000mm to 4000×3000×3000mm
Full support: Installation, commissioning, operation training, and technical support – prompt after-sales response